2012/11/04

Envrionmental Chiller


Categories: Water Cooled Environmental Industrial Chiller (HTI-W)
Brand:HERO-TECH
Type:Water-Cooled
Certification:CE, Other
Cooling Capability(kw):60kw to 200kw


Detailed Info
Water cooled industrial chiller
Features of HTI series (standard industrial chillers):
· CE standard design,
· R407c, R410A friendly type refrigerant,
· Panasonic/Hitachi (1/2HP, 1PH, 1.5HP, 2HP), Copeland or Danfoss (3HP to 60HP) world famous hermetic scroll compressor,
· Domestic or world famous brand Stainless steel pump,
· Stainless steel built-in tank,
· Door mounted disconnect switch,
· Original Schneider electrical components,
· Standard operating and safety controls
· Ventilated control cabinet
· Indoor operation
· Water-proof electrical chamber
· Removable panels for easy service access
· Mounted Casters
· Tank level alarm/switch, High and Low pressure switch, Inner thermostat for compressor motor, three phase over current protection, compressor overload protection, fan overload protection(air cooled), pump overload protection
· Shell and tube condenser (for water cooled Industrial chiller)
· Low noise and high efficiency finned tube condenser (air cooled Industrial chiller)


Remarks:
the nominal cooling capacities are based on the following conditions:
coolant supply 7C, return 12C, temperature difference 3C to 8C;
cooling water inlet 25C, outlet 30C, temperature difference 3.5C to 10C;
If you have any special requirements, please keep us noted.
Specifications, appearances and dimensions are subject to change without notice.


KeyWords:



envrionmental chiller



2012/10/27

Industrial Air Cooled Chiller--62kw To 134kw


Categories: Air Cooled Environmental Industrial Chiller (HTI-A)
Brand:HERO-TECH
Model:HTI-25AD,HTI-30AD,HTI-40AD,HTI-50AD
Type:Air-Cooled
Certification:CE, Other
Cooling Capability(kw):60kw to 135kw


Detailed Info

Features of HTI series (standard industrial chillers):
· CE standard design,
· high COP:2.88 to3.0,
· R407c, friendly type refrigerant,
· Copeland or Danfoss world famous hermetic scroll compressor,
· Stainless steel pump,
· Stainless steel built-in tank,
· Door mounted disconnect switch,
· Original Schneider electrical components,
· Standard operating and safety controls
· Ventilated control cabinet
· Indoor operation
· Water-proof electrical chamber
· Removable panels for easy service access
· Tank level alarm/switch, High and Low pressure switch, Inner thermostat for compressor motor, three phase over current protection, compressor overload protection, fan overload protection(air cooled), pump overload protection
· Low noise and high efficiency finned tube condenser

Parameter table 
ModelHTI-25ADHTI-30ADHTI-40ADHTI-50AD
nominal cooling capacitykw62.178.3106.34134.3
power source3PH 380V-415V 50HZ
refrigeranttypeR407C,R410A
controlThermostatic expansion valve
compressortypehermetic scroll
powerkw10.8*213.62*218.78*223.6*2
condensertypefinned copper tube + low noise outer rotor fan
evaporatortypeCopper coil built-in storage tank
coolant flowm3/h10.0613.617.7521.9
tank volumeliter350420580580
inlet and outletinch2-1/22-1/233
dimensionlengthmm2150215026502200
widthmm1050105012001780
heightmm2100210022002200
weightkg81089011121320


2012/10/25

Laser Chiller--air Cooled Chiller 50kw To 134kw


Categories: Laser Chiller
Brand:HERO-TECH
Model:HTL-20AD,HTL-25AD, HTL-30AD
Type:Air-Cooled
Certification:CE, UL, Other
Cooling Capability(kw):50KW TO 150KW


Detailed Info
Specification------Laser chiller---- air cooled

Product introduction


In laser system, laser source and beam controller would need to be cooled. Cooling water is normally required in the range of 15℃ to 22℃, with ±1℃ or ±2℃ accuracy and sometimes within ±0.1℃. Laser has special requirements for conductivity and corrosiveness of cooling water, normally water loop should be stainless steel materials.

Application

Laser chiller is mainly applied for laser marker, laser engraving machine, laser welder, laser cutting machine, laser ink jet machine, etc., for maintaining required temperature of laser equipment, so to ensure normal running.

Design features

¨ Large volume SS storage tank and SS coil evaporator.
¨ Built-in high pressure stainless steel chilled water pump, ensuring water quality and pressure.
¨ Well-known brand exhaust fan with large volume,excellent heat dissipation and low noise.
¨ Precision filtering device can be offered upon request, including particulate matter filtration and deionizer, ensuring high cooling water quality, extending laser and chiller's service life.
¨ Multi-protection devices: flow switch , water pressure switch, acoustic and optical alarm system.
¨ Protection signal output: water flow alarm signal output, water level alarm signal output, temperature protection alarm signal output, ensuring laser and chiller running safely.

Parameter table
ModelHTL-20ADHTL-25ADHTL-30AD
nominal cooling capacitykw51.859.584
power source3PH 380V-415V 50HZ
refrigeranttypeR22
controlThermostatic expansion valve
compressortypehermetic scroll
powerkw8.96*210.08*213.62*2
condensertypefinned copper tube + low noise outer rotor fan
evaporatortypestainless steel tank with copper coil built-in or Plate heat exchanger
coolant flowm3/h8.8410.0613.6
Tank volumeliter350350420
inlet and outletinch22-1/22-1/2
dimensionlengthmm195021502150
widthmm95010501050
heightmm196021002100
weightkg65011121320


2012/10/23

Air Cooled Low-temp Chiller 40HP To 60HP


Categories: Air Cooled Low Temperature Screw Chiller (HTSL-A)
Brand:HERO-TECH
Model:40HP 50HP 60HP
Type:Air-Cooled
Certification:Other
Cooling Capability(kw):32KW TO 95KW


Detailed Info

Air cooled low-temperature chiller

Specification
ModelHTSL-100AHTSL-130AHTSL-140A
nominal cooling capacity-10Ckw648592
-20C435661
-30C324245
power source3PH 380V 50HZ
refrigeranttypeR22、R404A
controlThermostatic expansion valve
compressortypeSemi-hermetic screw
powerkw405055
condensertypefinned copper tube + low noise outer rotor fan
evaporatortypeShell and tube
inlet and outletinch334
dimensionLengthmm265022002500
Depthmm120017601850
Heightmm220022002150
weightkg135016501950
Remarks:
1. norminal cooling capacity according to:
coolant temperature difference from 3C to 8C;
cooling air inlet 30C, outlet 38C;
2. chiller should be used under 40C ambient temperature;
3. Specification, appearances and dimensions are subject to change without notice.


2012/10/22

Screw Chiller---AIR COOLED 140kw To 220kw


Categories: Air Cooled Screw Chiller (HTS-A)
Brand:HERO-TECH
Type:Air-Cooled
Certification:CE, UL, Other
Cooling Capability(kw):160KW to 220KW


Detailed Info

screw chiller AIR COOLED

Design Features
¨ W shape aluminum fin type condenser, assuring adequate heat exchanging area within smaller unit size
¨ High efficient evaporator with internal thread copper tube.
¨ Large air volume axial fan with metal blades. Motor separated from net-cover, fixed on exhaust port by metal
¨ Siemens PLC control, LCD touch screen interface.
¨ Standard design charged R22, CFC Free R407C, R410A,R404A,R134A for option.
¨ 380V-415V/50HZ 3PH for standard design. Different design on customers' request.

Parameter table
ModelHTS-170AHTS-190AHTS-220A
nominal cooling capacitykw167184216
power source3PH 380V 50HZ
refrigeranttypeR22
controlThermostatic expansion valve
compressortypeSemi-hermetic screw
powerkw677382
condensertypefinned copper tube + low noise outer rotor fan
evaporatortypeShell and tube
Flow ratem3/h28.732.237.2
inlet and outletinch444
dimensionLengthmm295032003500
Depthmm195019501950
Heightmm220022002200
weightkg220023502550
Remarks:
1. norminal cooling capacity according to:
coolant inlet inlet 7C, outlet 12C, temperature difference from 3C to 8C;
cooling air inlet 30C, outlet 38C;
2. chiller should be used under 40C ambient temperature;
3. Specification, appearances and dimensions are subject to change without notice.



2012/10/21

Air Cooled Laser Chiller


Categories: Laser Chiller
Brand:HERO-TECH
Model:HTL-20AD,HTL-25AD, HTL-30AD
Type:Air-Cooled
Certification:CE, UL, Other
Cooling Capability(kw):50KW TO 150KW


Detailed Info
Specification------Laser chiller---- air cooled

Product introduction


In laser system, laser source and beam controller would need to be cooled. Cooling water is normally required in the range of 15℃ to 22℃, with ±1℃ or ±2℃ accuracy and sometimes within ±0.1℃. Laser has special requirements for conductivity and corrosiveness of cooling water, normally water loop should be stainless steel materials.

Application

Laser chiller is mainly applied for laser marker, laser engraving machine, laser welder, laser cutting machine, laser ink jet machine, etc., for maintaining required temperature of laser equipment, so to ensure normal running.

Design features

¨ Large volume SS storage tank and SS coil evaporator.
¨ Built-in high pressure stainless steel chilled water pump, ensuring water quality and pressure.
¨ Well-known brand exhaust fan with large volume,excellent heat dissipation and low noise.
¨ Precision filtering device can be offered upon request, including particulate matter filtration and deionizer, ensuring high cooling water quality, extending laser and chiller's service life.
¨ Multi-protection devices: flow switch , water pressure switch, acoustic and optical alarm system.
¨ Protection signal output: water flow alarm signal output, water level alarm signal output, temperature protection alarm signal output, ensuring laser and chiller running safely.


KeyWords:




2012/10/18

Air Cooled Low-temp Chiller 40HP To 60HP


Categories: Air Cooled Low Temperature Screw Chiller (HTSL-A)
Brand:HERO-TECH
Model:40HP 50HP 60HP
Type:Air-Cooled
Certification:Other
Cooling Capability(kw):32KW TO 95KW

Specification
ModelHTSL-100AHTSL-130AHTSL-140A
nominal cooling capacity-10Ckw648592
-20C435661
-30C324245
power source3PH 380V 50HZ
refrigeranttypeR22、R404A
controlThermostatic expansion valve
compressortypeSemi-hermetic screw
powerkw405055
condensertypefinned copper tube + low noise outer rotor fan
evaporatortypeShell and tube
inlet and outletinch334
dimensionLengthmm265022002500
Depthmm120017601850
Heightmm220022002150
weightkg135016501950


Remarks:
1. norminal cooling capacity according to:
coolant temperature difference from 3C to 8C;
cooling air inlet 30C, outlet 38C;
2. chiller should be used under 40C ambient temperature;
3. Specification, appearances and dimensions are subject to change without notice.